Grizzly G1006 User Manual Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 23
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
-20-
V-Belts
Inspect regularly for tension and wear. Replace
when necessary with a size B-42 belt for the spin-
dle pulley to the idler pulley belt and a size B-34
belt from the idler pulley to the motor pulley belt.
Check pulleys to ensure that they are properly
aligned.
Lubrication
Points requiring periodic lubrication are:
1. The main column. A light film of oil will
smooth action and prevent rust and corro-
sion.
2. The quill. A light coating of oil will ensure
smooth movement.
3. The quill return spring. Oil annually with a
light lubricant (SAE 20). Apply with a brush
or squirt can.
4. The quill pinion. Lubricate every 90 days
with non-hardening grease.
5. The table leadscrews. Lubricate once each
week with several drops of SAE 20.
6. The table leadscrew bearings. Lubricate
the bearings located at the ends of the table
and just in front of the Y axis hand crank on
a daily basis. You will find oil ports with a
ball. Apply a small amount of SAE 20 using
the oil can’s tip to push in the ball.
7. The table and apron slides. Lubricate the
table slides daily. An oil port with a ball is
located on the operators side of the table
edge. The apron slide can be oiled directly.
Make sure to carefully clean chips and dirt
off of this slide before oiling.
DO NOT make adjustments while the
Mill/Drill is running. Ensure that the switch
is off, power is disconnected and moving
parts have stopped before making adjust-
ments.
The internal quill pin is a setscrew and has
been pre-adjusted at the factory. It should not
need adjustment under normal circum-
stances.
The slotted setscrew on the left side of the head
is used for limiting the amount of rotational play
in the quill body. Loosening the check-nut and
tightening the setscrew will work to eliminate this
play in the quill.
If you are worried that you might have exces-
sive quill play, spindle looseness or if an acci-
dent has occurred that requires this
setscrew’s readjustment, contact the Service
Department for advice.
Quill
G1006/G1007 Mill/Drill
Page view 19
1 2 ... 15 16 17 18 19 20 21 22 23

Comments to this Manuals

No comments